Garnet 709-P3 RV Tank Monitor Wiring & Sender Installation - Manual Page 13
RV tank-level monitor install page: cut 3in x 1-7/8in display hole, use butt connectors or solder; wiring table maps Red 18ga +12V power, Black ground, Blue tank senders, White pump ground.
This document is page 13 of the Garnet Instruments 709-P3 RV tank monitor installation manual, photographed alongside the back of the actual 709-P3 display circuit board. The page provides installation steps for the tank monitoring system: it references Chapter 7 troubleshooting tips, describes mounting the display inside the RV by cutting a 3" wide by 1-7/8" high hole in the wall, and warns against spade connectors (crimp butt connectors or solder only). A wiring table lists four 18-gauge wires: Red (+12V power input to monitor), Black (Ground), Blue (Tank senders), and White (Pump indicator). The senders must be grounded to a single ground wire from the display, with system ground tied to the breaker panel ground. Steps 5 and 6 cover sender placement on holding tanks — requiring a flat contact area, metal clearance of at least 1" from the sides/top/bottom and 2" from the sender face, and clean surfaces for adhesive — plus measuring tank height to select sender configuration. A caution warns not to mix sender types when stacking. The photographed board shows labels: 709-P3, Made in Canada, CAN ICES-003(B)/NMB-003(B), a California Prop 65 warning, serial label 709-P3-053243, and a board date of 2018-02-20.
Is this accurate? Sign in to help verify it.
Frequently asked questions
- What do the wire colors mean on the Garnet 709-P3 tank monitor?
- Red 18 gauge is +12V power input to the monitor, Black 18 gauge is Ground, Blue 18 gauge is Tank senders, and White 18 gauge is Pump indicator.
- What size hole is needed to mount the 709-P3 display?
- Cut a hole in the wall 3" wide by 1-7/8" high and bring the wiring out through the hole to connect to the display panel connector.
- Can I use spade connectors when wiring the 709-P3?
- No. The manual says DO NOT use spade connectors to join wires — only use crimp-on butt connectors or solder the wires together.
- How much clearance from metal do the tank senders need?
- Any metal must be at least 1" away from either side or the top and bottom of the sender, and at least 2" away from the face of the sender.
- How are the senders grounded?
- The senders need to be grounded to a single ground wire from the display, and the system ground must be connected to the breaker panel ground.