1993 Ford Bronco
Owner: SigEpBlue 
From: Ida & Grand Rapids, MI, U.S.A.        (Other registries in MI)
Year, Make, & Model: 1993 Ford Bronco        (Other Ford Broncos)
Avatar:
Nickname: Balios
Mileage: 160000
Engine: 5.8L F4TE factory short block, factory Mustang roller camshaft, GT40P cylinder heads, customized Pace-Setter headers, Explorer intake manifold, 65mm throttle body, 67mm EGR spacer, 130A 3G alternator, Ford Racing underdrive pulleys, mass-air conversion (BIO0 PCM), Mustang cooling fan & clutch, 4-row copper/brass radiator, custom DPFE system for proper EGR flow.
Drivetrain: All-factory stuff: personally-tweaked E4OD, BW1356 electronic transfer case, 8.8-inch Traction-Lok rear differential, Dana 44 open front differential, 3.55 / 3.54 gears, respectively.
Notes: Rescued from a Chevy dealer just West of Lansing, MI in November of 2005 by divine intervention.
The name, Balios, comes from one of two immortal horses Peleus gave to Achilles. The other, Xanthos, is my notchback Mustang. http://en.wikipedia.org/wiki/Balius_and_Xanthus
Last Updated: 8/28/2008
Hits: 1597
Album
Folder Hits Comments Created Updated
folder Balios10026907/26/088/28/08
folder Forum Pics10036008/23/088/23/08
Newest Media Files
This was a test of my Sunpro temperature gauge.  Note that the pot of water is boiling, and that the gauge is indicating 206°F.

The barometric pressure at the time was 29.89inHg, which means the boiling point of water was 211.94°F..

Calcu...
SunproGaugeError_29pt89inHgBarometricPressure.jpg
269 hits | 48.83 KB | Posted: 8/28/08

This was a test of my Sunpro temperature gauge. Note that the pot of water is boiling, and that the gauge is indicating 206°F.

The barometric pressure at the time was 29.89inHg, which means the boiling point of water was 211.94°F..

Calcu...
Intake On Seat_hilite.jpg
Intake On Seat_hilite.jpg
360 hits | 43.36 KB | Posted: 8/23/08

Most Viewed Files
Intake On Seat_hilite.jpg
Intake On Seat_hilite.jpg
360 hits | 43.36 KB | Posted: 8/23/08

This was a test of my Sunpro temperature gauge.  Note that the pot of water is boiling, and that the gauge is indicating 206°F.

The barometric pressure at the time was 29.89inHg, which means the boiling point of water was 211.94°F..

Calcu...
SunproGaugeError_29pt89inHgBarometricPressure.jpg
269 hits | 48.83 KB | Posted: 8/28/08

This was a test of my Sunpro temperature gauge. Note that the pot of water is boiling, and that the gauge is indicating 206°F.

The barometric pressure at the time was 29.89inHg, which means the boiling point of water was 211.94°F..

Calcu...