SuperMotors SuperMotors SUPERMOTORS Search — try “orange Bronco on 35s”
Home/ Registry/ Ford/ LTD Crown Victoria/ 1983-1991/ 1991 Ford LTD Crown Victoria/ Photo supermotors.net/registry/media/954556

MEP-005A 30kW Military Diesel Generator Data Plate - Specs & Ratings

DoD generator data/spec plate listing model MEP-005A ratings, kilowatt capacity by altitude, voltages, and phases.

AI caption · Photo 3461 of 4575

This photograph shows two riveted metal data/spec plates on a US Department of Defense generator set — a diesel-engine MEP 005A generator rated at 30 kW, 50/60 Hz. The upper identification plate lists the model (MEP 005A), Federal Stock Number (FSN 6115-118-1240), serial number (KZO 8594), registration number (6115), applicable technical manuals (TM 5-6115-465-12, TO 35C2-3-446-1, NAV FAC P-8-625-12, TM 06858B-12), dry weight (2850 lb), dimensions (80 in long, 36 in wide, 55 in high), and a manufacture date of 7-86 (July 1986). The lower plate is a kilowatt capacity/derating chart giving output at different altitudes and temperatures (25/30 kW at 5000 ft and 107°F, 25/30 kW at 6000 ft and 103°F, 22.5/27 kW at 8000 ft and 95°F), the 50/60 Hz rating, rated voltages and phases (240/416 V and 120/208 V, 3-phase at both 50 and 60 Hz), voltage adjustment ranges (395/480 and 197/240 V at 60 Hz; 380/426 and 190/213 V at 50 Hz), and a power factor of 0.8. Readers can learn the generator's identity, capabilities, altitude derating, and manual references.

This document covers 1986, which may differ from this 1991 Ford LTD Crown Victoria.

Is this accurate? Sign in to help verify it.

Frequently asked questions

What model is this military generator?
It is a US Department of Defense MEP 005A generator set, diesel engine, 30 kW, 50/60 Hz, FSN 6115-118-1240.
What are the rated voltages of the MEP 005A?
240/416 V and 120/208 V, 3-phase, at both 60 Hz and 50 Hz, with voltage adjustment ranges of 395/480 and 197/240 V (60 Hz) and 380/426 and 190/213 V (50 Hz).
How does altitude affect the generator's kilowatt output?
Per the capacity plate: 25/30 kW at 5000 ft (107°F/41.7°C), 25/30 kW at 6000 ft (103°F/39.5°C), and 22.5/27 kW at 8000 ft (95°F/35°C).
What does the MEP 005A weigh and what are its dimensions?
Dry weight is 2850 lb; length 80 in, width 36 in, height 55 in.
Which technical manuals cover this generator?
TM 5-6115-465-12, TO 35C2-3-446-1, NAV FAC P-8-625-12, and TM 06858B-12.

Comments

No comments yet.

More from this build

Close-up of a vehicle's radiator and lower grille area, showing dust and debris Undercarriage view of a vehicle's front tire and suspension system Trunk interior showing metal bracing, carpet lining, and red wiring harness Spare tire in the trunk of a car, with a speaker visible on the ceiling Trunk interior showing carpet, spare tire, and a yellow warning sticker Dark gray textured surface, possibly interior trim or fabric Spare tire and jack in a dark gray carpeted trunk, with a portion of the trunk lid visible Interior shot of a car's headrest and seat. Some blue marks are visible on the fabric