Service manual chart of MLP sensor pin 30 voltages for each tran…
A scanned service-manual chart labeled "MLP Voltage (Pin 30)" listing manual lever position sensor voltages for each gear range: Park 4.4v, Reverse 3.6v, Neutral 2.8v, Drive 2.1v, Manual Second 1.4v and Manual Low 0.7v, captioned Figure 3.
MLP Voltage (Pin 30) Park ...................................... 4.4V Reverse ................................ 3.6V . 2.8V . 2.1V 1 .4V 0,7V Neutral Drive Manual Second .................. Manual Low ........................ Figure 3