Hyundai Genesis Ambient Temperature Sensor - Resistance Specs & Test Procedure
Service manual page describing the ambient temperature sensor, including a temperature-vs-resistance specification table and inspection procedure
This service manual page covers the ambient (outside air) temperature sensor for a Hyundai Genesis-family vehicle. The Description section explains that the sensor is mounted at the front of the condenser and is a negative-coefficient thermistor whose resistance increases as temperature drops and decreases as temperature rises. Its signal is used for discharge temperature control, temperature regulation door control, blower motor level control, mix mode control, and in-car humidity control. A notice states that if ambient temperature falls below 2.0°C (35.6°F), the A/C compressor is stopped and can only be operated manually. The Inspection procedure instructs: turn the ignition OFF, disconnect the sensor, and measure resistance between terminals 1 and 2 while ambient temperature changes. A specification table lists resistance values at six temperatures, ranging from 163.31 kΩ ±3% at -10°C down to 16.032 kΩ ±3% at 40°C (e.g., 30 kΩ ±3% at 25°C/77°F). An illustration (reference AQJF204B) shows an ohmmeter connected across the sensor's connector terminals. If measured resistance is out of specification, a known-good sensor should be substituted; if that corrects the problem, the sensor should be replaced.
Is this accurate? Sign in to help verify it.
Frequently asked questions
- Where is the ambient temperature sensor located?
- It is located at the front of the condenser and detects ambient air temperature.
- How do I test the ambient temperature sensor?
- Turn the ignition OFF, disconnect the sensor, and check the resistance between terminals 1 and 2 while the ambient temperature changes, comparing readings to the specification table.
- What resistance should the ambient temperature sensor read at 25°C (77°F)?
- 30 kΩ ± 3% between terminals 1 and 2.
- Why does the A/C compressor stop in cold weather?
- If the ambient temperature is below 2.0°C (35.6°F), the A/C compressor will be stopped; the compressor can then be operated by manual operating.
- What systems use the ambient sensor signal?
- Discharge temperature control, temperature regulation door control, blower motor level control, mix mode control, and in-car humidity control.